回答済み
How can I get the parameters of a MATLAB Function programmatically on command line
For a specific Matlab Function block, as asked in the question (I have a simple Matlab Function block in my model with one input...

3年弱 前 | 0

回答済み
Simulink State Space Error
Hi Dylan, Unclear why the error message refers to "Project1/Step" when the model apparently does not contain a Step block. Any...

3年弱 前 | 1

| 採用済み

回答済み
IMU sensor fusion: imufilter command reduces number of samples
Hi Aishwarya, Because the decimation factor is 2, shoudn't it be expected that there be half as many output samples as there ar...

3年弱 前 | 0

回答済み
Using a persistent array in a Simulink function block
Hi richard, The typical structure would look like this: function [a11, a12, a21, a22, b1, b2] = fcn(I_in, V_out, U_in) persis...

3年弱 前 | 0

| 採用済み

回答済み
simple test for nufft not working
Hi Pieter, I don't think that expression for Y(k) is correct. We can check symbolically %% define signal t = sym([-1.0,1.0]);...

約3年 前 | 0

| 採用済み

回答済み
In kalman filter, the elements of state transition matrix using fourth-order runge-kutta integration
Hi Chong-You, It sounds like the system is linear and time invariant. In continuous time, the state dynamics are: xdot(t) = A...

約3年 前 | 0

回答済み
Using Bus in Simulink
Does Load Data using the From Workspace Block include an example that will help?

約3年 前 | 0

回答済み
Error using symfun/subsref (line 203) Invalid argument at position 2.
Hi Catalina, Need to subscript N in the foor loop to create a vector with 3 elements. Also, the final construction of N had an ...

約3年 前 | 0

回答済み
Convert cell array of string arrays to a single string array
Hi Charles Use vertcat with a comma separated list as the input my_cell = cell(5,1); % Assign some values my_cell{1} = "even...

約3年 前 | 0

| 採用済み

回答済み
Function writing in MATLAB in symbolic format
It appears that the symfun objects have to have the same arguments (number and order) to add them syms rho(x,y,z,t) rho_m(x,y,z...

約3年 前 | 0

回答済み
How to input exponentials in transfer functions using Simulink?
In addition to using a single transfer function along with gains and transport delays as suggested by @Sam Chak, if you have the...

約3年 前 | 0

回答済み
How to use a from workspace function for a 1D lookup table
Dose input_grafiek have a constant value over the entire simulation run? If it does, don't use a From Workspace block. Instead, ...

約3年 前 | 0

| 採用済み

回答済み
Get Intermediate Signal of Block Diagram for Control System
Hi Ian, AFACIT, you did everything correctly as far as defining and connecting the diagram. With the PID controller defined, th...

約3年 前 | 1

| 採用済み

回答済み
How can i remove (or hide) the time units ("(seconds)") from the stepplot graphic in the x-axis?
If you're willing to accept 'hours' in the label instead of 'horas' then set the TimeUnit property of M numM=[1.123]; denM=[1 ...

約3年 前 | 0

| 採用済み

回答済み
Binärsignal transformation 100 [Hz] --> 2000 [Hz]
Hi julius, Does repelem meet the requirement. Here's a small example to repeat each element three times (instead of 20) to mak...

約3年 前 | 0

回答済み
How to test if an object is a simulink.parameter ?
Hi Alexandre Use find on dictionary section object to find the entries that meet the desired criterion. >> myDictionaryObj = S...

約3年 前 | 1

| 採用済み

回答済み
Error: Simulink Scope Block does not support 'Array' format for logging matrix signals
Why not use a To Workspace block? If haven't done already this doc page is a good place to start to compare all options. In ...

約3年 前 | 0

| 採用済み

回答済み
Simulink error: Time-Varying State Space block
Hi John, In the Constant blocks for sys_lqr.B and sys_lqr.C try clearing the block parameter "Interpret vector parameters as 1-...

約3年 前 | 1

回答済み
recreating nyquist regions using FFT
Are the "third" and "fourth" Nyquist zone the frequencies from Fs to 3*Fs/2 and from 3*Fs/2 to 2*Fs respectively? If so, third...

約3年 前 | 0

質問


Did mldivide Implementation Change in R2022b?
When I run this code here on 2022b (actually, 2023a now, but I saw the same effect on 2022b) I get: load('mldivdivideex') form...

約3年 前 | 1 件の回答 | 0

1

回答

回答済み
why do my spectrogram values are negative and how to read them?
The power levels are in dB. Any positive number less than 1 is negative when converted to dB pow2db(0.5) See pow2db.

約3年 前 | 0

回答済み
How to use Cell array as block parameter using setBlockParameter in Simulink?
Hi David-ucr, I don't have 2022b and can't find EVModel in 2022a, so can't test. I also couldn't find it on the 2022b Simulink ...

約3年 前 | 0

| 採用済み

回答済み
Resample function is not working properly and damaging the signal
Hi goksu, The observed behavior is documented at resample specifcally here: "... resample assumes that the input sequence, x, ...

約3年 前 | 2

回答済み
Transfer function matrix of a Multiple input DC-DC converter
Does linearize work on Simulink Simscape models?

約3年 前 | 0

回答済み
use green therom to find counter clockwise circulation and outward flux
Isn't the answer 0? Using the approach referenced here syms x y real % vector field F = [7*x-3*y, 7*y-3*x]; % Define the ...

約3年 前 | 0

回答済み
Subsystem with similar functionality as of "Unit Delay"
Does the Delay block meet the need? It can accept an IC from an external source and is externally resettable.

約3年 前 | 0

回答済み
Magnitude of a vector with unit
Looks like simplify pulls the unit^2 out of the root u=symunit; x=[1 2 3]*(u.m); norm(x) simplify(norm(x)) vpa(ans) x=[1 2...

約3年 前 | 1

| 採用済み

回答済み
Extract time signal of specific frequences from a given time series signal
Hi Chenghao, I suspect the issue is related to the duration of x relative to the dynamics of the transient response of the filt...

約3年 前 | 0

回答済み
fft2 results don't match the analytical Fourier transform results
Hi Seyedalireza, The code below get closer, maybe all the way there, by addressing a few issues % Define the dimensions of the...

約3年 前 | 1

| 採用済み

回答済み
ODE45 error must return column vector
Try doing what the error message says and make sure that F is a column vector. Here's one option dFdt = [dCadt ; dCbdt ; dCcdt]...

約3年 前 | 0

| 採用済み