回答済み
Can System Composer or other MathWorks tools be used to create Product Line Models (some call them Feature Models)?
Hi Brian, Yes, this can be done using System Composer. Feel free to reach out to us through your sales rep if interested in ha...

約1年 前 | 0

| 採用済み

回答済み
slreq.find error searching requirements with a specific stereotype property.
Hi @Alberto Estrada, This is a known limitation in 23a. Here's a workaround for you: reqs = slreq.find(Type='Requirement', R...

約1年 前 | 1

| 採用済み

回答済み
System Composer Traceability Matrix - How do you display both Requirement ID and its Summary?
Hey @Daniel Hunt, The traceability matrix displayed attributes are not configurable but it does show the ID attribute so you co...

約1年 前 | 1

| 採用済み

回答済み
Getting the properties value of connector destination port in system composer
Hi @Sarvesh, If the connector is between input/output ports then you can use the SourcePort and DestinationPort properties of t...

1年以上 前 | 1

| 採用済み

回答済み
Simulink data dictionary is not supported by MicroAutoBox II's RTI?
Hi @Barry, MicroAutoBox and RTI are both dSPACE products. I recommend reaching out to them directly: https://www.dspace.com/en...

1年以上 前 | 0

回答済み
Simulink Requirement Editor: Import from spreadsheet including hierarchy
Hi @Christian, I confirmed that this issue existed in R2021b and was resolved in R2022a. Josh

1年以上 前 | 0

回答済み
Tips to convert a subsystem into Requirement Table block
Hey @Shubham, Local data is not stored between timesteps so there is no prev(value). If you want to use a variable that persist...

1年以上 前 | 0

| 採用済み

回答済み
Understanding initial behavior of Requirement Table
Hi @Shubham, In R2022a, the getPrevious function is undefined at t = 0 so you will need to an alternative, such as isStartup, t...

1年以上 前 | 0

| 採用済み

回答済み
Renaming All Ports on a Connector Node - System Composer
Not through the GUI (only happens when all ports have default names) but you can do it programmatically. You could also create a...

1年以上 前 | 0

回答済み
Big sized autosar software component after arxml import in system composer
When we import arxml files, it is not just the information for building the skeleton model, but also can contain the aspects of ...

1年以上 前 | 0

回答済み
How to connect ports with system composer using the dot notation for buses programmatically?
Hi @Enrico, Use the SourceElement and DestinationElement arguments of the connect API: https://www.mathworks.com/help/systemco...

1年以上 前 | 1

回答済み
How do I link requirements in Requirements Manager to Simulink blocks inside of a Referenced Subsytem?
Hi @Moe, To preserve modularity, I recommend that you open the subsytem as top model and link the requirements there. If this i...

1年以上 前 | 0

| 採用済み

回答済み
Can we print the contents of Requirements tagged in Simulink model to a command window? (Details in Description)
Hi @Akshay Chandel, Hope you got this resolved by now but just in case you haven't, you can load the model's linkset file and i...

1年以上 前 | 0

回答済み
Invalid ReqIF file. Error details: Type 'reqifxhtml:div' has not been found in the registry.
Problem resolved by replacing: xmlns:reqif-xhtml="http://www.omg.org/spec/ReqIF/20110401/reqif-xhtml" with: xmlns:reqif-xhtml...

1年以上 前 | 0

回答済み
Is there a way to recreate/replace links from Simulink models to requirement in DOORS with links to requirements in Polarion programmatically?
Hi @Isaac, The Polarion Connector is a third party tool created for integrating between Polarion and Requirements Toolbox for m...

1年以上 前 | 0

回答済み
Link between two components exists in system composer, but cannot be traced in sequence diagrams
Hi @Loic, Can you please try pressing the "Check Consistency" button in the toolstrip and then the "Repair" button and let us k...

1年以上 前 | 0

回答済み
Is it possible to connect Simulink Electrical components to the ports of Component in System Composer?
Hi @Sai Sanjay, Yes, you can absolutely use physical signals and buses in System Composer. Simscape signals are not allowed to ...

1年以上 前 | 0

回答済み
Add Adapter programatically to system composer model
Hi @Andreas, There is no API for creating adapters but you can create a component that performs the same actions using the Sour...

1年以上 前 | 0

回答済み
Requirements toolbox : links (type : related) do not appear when exporting to Excel, using ReqXLSExport method
Hi @Loic, I think you are looking for "Relate" <links-in:Relate>. Let us know if you have any other issues. You can find the...

1年以上 前 | 1

| 採用済み

回答済み
Export traceability matrix into variable
Hi @Niranjan Joshi, I was able to confirm the behavior you are seeing and entered it as a bug. Thanks for letting us know! As f...

1年以上 前 | 0

回答済み
How to use a scheduler in System Composer?
Hi @Amine, To use the schedule editor, first, ensure that your architecture model was created using the "Software Architecture ...

1年以上 前 | 0

回答済み
TI micro controller like hardware are supported for matlab simulation using code composer studio and also can we develop library using firmware data?
Hi @Rakesh, Code Composer Studio is a third party tool. I recommend you reach out to TI directly for support: https://support....

1年以上 前 | 0

| 採用済み

回答済み
How do you resize (shrink) the base model or canvas in System Composer?
Hi @Gergely, To fit the canvas to the architecture model, press the space bar twice. Hope this helps, Josh

1年以上 前 | 0

| 採用済み

回答済み
Signal merging : adapters do not show up in architecture views
Hi @Loic, I am assuming that you are filtering on an applied stereotype and that is making your adapters disappear. One way to ...

1年以上 前 | 0

| 採用済み

回答済み
Linear analysis not found
Hi @NITHIN PRANESH, I see that you posted this in the System Composer category so I am assuming you are referring to analysis o...

1年以上 前 | 0

回答済み
Cycle through components according to stereotype
Hi @Loic, System Composer has a query feature that is optimized for these kinds of search tasks. The API list for the query lan...

1年以上 前 | 1

| 採用済み

回答済み
How can I know which file identifiers correspond to open files?
Also, if you want to avoid this, you can now use a cleanup object to close the file when the function is done (error or normal) ...

1年以上 前 | 0

回答済み
Cancelling a variation on a system composer component
Hi @Loic, Right-click the variant choice that you want to keep and choose "cut", navigate back to the composition, then right-c...

1年以上 前 | 1

| 採用済み

回答済み
what is the difference between simulink architecture model and software architecture model
Hi @Xiaohong shen, That is a great question! System Composer's standard Architecture Template is geared toward generic architec...

1年以上 前 | 0

回答済み
Code generation with a System Composer model
Hi @antonio-deepware, Do either of these options solve your problem? Option 1: Include the software architecture as a refere...

2年弱 前 | 0

| 採用済み

さらに読み込む