Community Profile

photo

Jonas


Last seen: 2日 前
65 2019 年以降の合計貢献数

Jonas's バッジ

  • First Review
  • 3 Month Streak
  • Revival Level 1
  • Knowledgeable Level 2
  • First Answer
  • Thankful Level 1

詳細を表示...

貢献した分野
表示方法

回答済み
Unavailable Simscape blocks in a 2019b model exported for 2018b
Are you sure you have installed all toolboxes on your MATLAB 2018b version? You need to install your necessary licenses for each...

2日 前 | 0

回答済み
Simulink Real-Time Speedgoat. Start the model at powerup??
The principle is called 'standalone boot'. Instructions and details can be found here. Quick summary: Open Simulink Real-time ...

2日 前 | 1

回答済み
Matlab/Simulink 2018a..Byte pack and unpack
Can you search the Simulink block library for 'byte unpack' and see if you have multiple of those blocks? It seems like you have...

2日 前 | 0

回答済み
Embedded Coder generated .zip file problem
The feature to generate a .zip package is in fact using the command 'packngo'. You could investigate that command in more detail...

13日 前 | 0

| 採用済み

回答済み
External mode on Simulink
I believe your system target file (the .tlc-file) may not be capable of External mode. You need to set it to something like slrt...

13日 前 | 0

| 採用済み

回答済み
Simulink powertrain model approach
If you are not able to use Simscape but just Simulink, you can try to model your components by using look-up tables and stateflo...

約1ヶ月 前 | 0

| 採用済み

質問


Sample time of Host Scopes in Simulink Real-time
Hi I am using Host Scopes to capture signal data of my model running on a Simulink Real-time target. My base model has a sample...

約2ヶ月 前 | 1 件の回答 | 0

1

回答

回答済み
Resolving Algebraic Loops in SIMULINK models
You can use an ODE solver to solve the differential algebraic equations an algebraic loop generates. However, this is not possib...

約2ヶ月 前 | 0

回答済み
How do I change an indivdiual user license in a designated pc license
Contact MathWorks support, they can change it.

約2ヶ月 前 | 0

質問


Get parameter value from named parameter in Simulink in Simulink Real-time
Hi all I am running a Simulink model using Simulink Real-time on a SpeedGoat target. I am using Simulink Parameters inside a Da...

2ヶ月 前 | 1 件の回答 | 0

1

回答

回答済み
Can't connect blocks in simulink
The block you are trying to connect produces a Signal as an output. You need to use a Controlled Voltage Source and provide the ...

4ヶ月 前 | 1

| 採用済み

回答済み
Setting/Tuning parameters of a Simulink model in Realtime
I believe Diego's suggestion will help. I would also suggest to use Simulink Parameter variables inside the Model workspace and...

4ヶ月 前 | 0

回答済み
Matlab and Nvidia cuda GPU
You can only run calculations on a GPU using the Parallel Computing Toolbox.

5ヶ月 前 | 1

| 採用済み

回答済み
How do I change the initial condition at time t=0 of an IC block to an external value ?
Hi You should try the implementation below: The IC block with initial condition [0] will make sure your model runs with an i...

5ヶ月 前 | 0

回答済み
Provide automatic delays to a signal
Use a Delay block Set it to receive the delay length from an Inport Feed your variable delay time through a triggered subsyste...

5ヶ月 前 | 0

| 採用済み

回答済み
Where can I find Documentation on Battery Modeling for simulink
https://nl.mathworks.com/solutions/power-electronics-control/battery-models.html

5ヶ月 前 | 0

回答済み
How to change background colour of display block with a change in input - Simulink
I suggest you take a look at the Simulink Dashboard elements. You can add a LED directly in your Simulink model which is linked ...

5ヶ月 前 | 0

回答済み
Can I implement a controller that uses an external physical device to control the simscape physical model motion?
If you want to combine a physical external signal with a Simscape model, you will need to run the Simscape model in real-time an...

5ヶ月 前 | 0

回答済み
Does the use of latency in statflow state work as expected?
Your state expression will not work indeed. You will need to create an additional state where ProtectStartBit = uint16(1); which...

5ヶ月 前 | 0

| 採用済み

回答済み
C Caller does not reflect changes in C-Code on Simulink Model
Could you try to go into your Simulink Configuration Parameters => Model Referencing and set Rebuild to Always. It may be ignori...

5ヶ月 前 | 0

回答済み
2019a Open model in new window
Are you opening a referenced model? They used to automatically open in a new window, while in 2019a now they are opened as if th...

5ヶ月 前 | 0

| 採用済み

回答済み
Array element(2x16) and display
Hi Please see the reference documentation for the Display block. It states that "The Display block shows the first 200 element...

5ヶ月 前 | 0

回答済み
split screen for simulink model subsystems
Right click a subsystem, and click 'Open in new Window'

5ヶ月 前 | 1

| 採用済み

回答済み
Updated to R2019a and have less toolboxes and than my R2018b version. Why?
The command ver will show you your installed toolboxes, not the toolboxes for which you have a license. The command may list ins...

6ヶ月 前 | 0

回答済み
Create a signal from vectors in simulink
I guess you are looking for the Mux block. It allows to combine separate signals into a vector signal.

6ヶ月 前 | 0

回答済み
Problem in PWM Block in Simulink Support Package for Arduino Hardware
Have you tried providing it with more than 255 as duty ratio? Are you sure the input needs to be an 8 bit signal (between 0 and ...

6ヶ月 前 | 0

回答済み
How do I design AC / DC / AC bi-directional inverter models?
The Simscape Electrical toolbox has a range of DC/DC, DC/AC and AC/DC/AC converters at your disposal. You can also go a deeper r...

6ヶ月 前 | 0

回答済み
Hello Every one! can some one please help me in connecting diodes with DC sources in simulink?
You cannot combine blocks from the Simscape Electrical toolbox with the blocks under 'Specialized Power Systems'. One should res...

6ヶ月 前 | 0

質問


Need to run sl_refresh_customizations each time I open my Simulink project
Hi I have created a custom target for my Simulink Embedded Coder code generation. The target is stored in a Target file inside ...

6ヶ月 前 | 1 件の回答 | 0

1

回答

回答済み
Simulink sample time with external sample clock?
I would suggest to put the digital filter in a triggered subsystem and use the 360 Hz signal as trigger.

6ヶ月 前 | 0

| 採用済み

Load more