simscapepower and other block connection error
1 回表示 (過去 30 日間)
古いコメントを表示
I am trying to create a model using simscape but the unable to make connections between current measurement block to another block. I tried with Simulink ps converter but still having the same problem.For detailed understanding, I attached the image file
0 件のコメント
回答 (1 件)
Andrew Schenk
2016 年 11 月 28 日
You cannot directly interface Simscape Power Systems Specialized Technology blocks with Simscape blocks. Consider replacing the Breaker block with the Simscape block https://www.mathworks.com/help/physmod/sps/ref/singlephasecircuitbreaker.html which will allow a direct connection.
Alternatively, use the following example to show how Specialized Technology blocks can be connected to Simscape blocks: https://www.mathworks.com/help/physmod/sps/powersys/ref/currentvoltagesimscapeinterface.html