The Three-Phase V-I Measurement block is used to measure instantaneous three-phase voltages and currents in a circuit. When connected in series with three-phase elements, it returns the three phase-to-ground or phase-to-phase peak voltages and currents. The three measured phase-to-ground or phase-to-phase voltages. The Vabc output disappears when the Use a label parameter is selected or when the Voltage measurement menu is set to no. The three measured line currents. The Iabc output disappears when the Use a label parameter is selected or when the Current measurement menu is set to no. So, I assume either the measurements are set to no or 'Use a label' is selected. If you use a label then you can use a From block to get the Vabc/Iabc measurements. If you don't use a label in the VI measurement then you'll have Vabc/Iabc measurements as outputs from the VI measurement. You can then use the Vabc/Iabc signals in your S function as needed, you might need to demux the signals. I hope this helps.