In the Solar Cell, what is meant by the Irradiance used for measurements, Ir0 parameter and what is its relation with the Solar Cell's Ir port?
0 件のコメント
回答 (1 件)
Sabin
2023 年 2 月 13 日
Ir0 is the irradiance that produces a current of Iph0 in the solar cell. The solar-generated current Iph is given by Ir*(Iph0/Ir0) where Iph0 is the measured solar-generated current for irradiance Ir0.