HRTIM
Use the higher resolution timer module and its parameters to configure the interrupts.
Suspend update events during preload write timers select
Enable to configure the timers to suspend update events during preload write timers.
Settings
Default:
off
on
Synchronized counter start timers select
Enable to configure the timers to synchronize counter start timers.
Settings
Default:
off
on
Enable interrupts select
Select the timer to enable the interrupts.
Settings
Default:
TimerA
TimerB
TimerC
TimerD
TimerE
TimerF
MainTimer
Global
Faults
Enable delayed protection trigger interrupt
Select this parameter to enable delayed protection trigger interrupt for the selected higher resolution timer module.
Settings
Default:
off
on
Enable counter reset/roll-over event interrupt
Select this parameter to enable counter reset/roll-over event interrupt for the selected higher resolution timer module.
Settings
Default:
off
on
Enable channel# reset interrupt
Select this parameter to enable channel# reset interrupt for the selected higher resolution timer module.
Settings
Default:
off
on
Enable channel# set interrupt
Select this parameter to enable channel# set interrupt for the selected higher resolution timer module.
Settings
Default:
off
on
Enable capture# event interrupt
Select this parameter to enable capture# event interrupt for the selected higher resolution timer module.
Settings
Default:
off
on
Enable update interrupt
Select this parameter to enable update interrupt for the selected higher resolution timer module.
Settings
Default:
off
on
Enable repetition event interrupt
Select this parameter to enable repetition event interrupt for the selected higher resolution timer module.
Settings
Default:
off
on
Enable compare# event interrupt
Select this parameter to enable compare event interrupt for the selected higher resolution timer module.
Settings
Default:
off
on
Enable register update event
Select this parameter to enable register update event for the selected higher resolution timer module.
To enable this parameter, set the Enable interrupts
select to MainTimer
.
Settings
Default:
off
on
Enable synchronization update event
Select this parameter to enable synchronization update event for the selected higher resolution timer module.
To enable this parameter, set the Enable interrupts
select to MainTimer
.
Settings
Default:
off
on
Enable DLL calibration done interrupt
Select this parameter to enable DLL calibration done interrupt for the selected higher resolution timer module.
To enable this parameter, set the Enable interrupts
select to Global
.
Settings
Default:
off
on
Enable burst period completed interrupt
Select this parameter to enable burst period completed interrupt for the selected higher resolution timer module.
To enable this parameter, set the Enable interrupts
select to Global
.
Settings
Default:
off
on
Enable system fault interrupt
Select this parameter to enable system fault interrupt for the selected higher resolution timer module.
To enable this parameter, set the Enable interrupts
select to Faults
.
Settings
Default:
off
on
Enable fault# interrupt
Select this parameter to enable system fault interrupt for the selected higher resolution timer module.
To enable this parameter, set the Enable interrupts
select to Faults
.
Settings
Default:
off
on