ドキュメンテーション

最新のリリースでは、このページがまだ翻訳されていません。 このページの最新版は英語でご覧になれます。

Simscape の Simscape ブロック

アルファベット順 カテゴリ別
Absolute Reference (2P) Reference point at zero absolute pressure and specific internal energy
Absolute Reference (TL) Reference point at zero absolute temperature and pressure
AC Current Source Ideal sinusoidal current source
AC Voltage Source Ideal constant voltage source
Adiabatic Cup Thermal element with no thermal mass and perfect insulation
Asynchronous Sample & Hold Output sample-and-hold signal with external trigger
Cap (2P) Perfectly insulated stop to fluid flow
Cap (TL) Perfectly insulated stop to fluid flow
Capacitor Linear capacitor in electrical systems
Conductive Heat Transfer Heat transfer by conduction
Connection Port Physical Modeling connector port for subsystem
Constant Area Hydraulic Orifice Hydraulic orifice with constant cross-sectional area
Constant Area Pneumatic Orifice Sharp-edged orifice in pneumatic systems
Constant Area Pneumatic Orifice (ISO 6358) Fixed-area pneumatic orifice complying with ISO 6358 standard
Constant Volume Chamber (2P) Rigid chamber with constant volume of two-phase fluid
Constant Volume Chamber (TL) Rigid chamber with constant volume of thermal liquid
Constant Volume Hydraulic Chamber Hydraulic capacity of constant volume
Constant Volume Pneumatic Chamber Constant volume pneumatic chamber based on ideal gas law
Controlled Current Source Ideal current source driven by input signal
Controlled Flux Source Ideal flux source driven by input signal
Controlled Mass Flow Rate Source (2P) Generate time-varying mass flow rate
Controlled Mass Flow Rate Source (TL) Generate time-varying mass flow rate
Controlled MMF Source Ideal magnetomotive force source driven by input signal
Controlled Pneumatic Flow Rate Source Ideal compressor with signal-controlled mass flow rate
Controlled Pneumatic Pressure Source Ideal compressor with signal-controlled pressure difference
Controlled Pressure Source (2P) Generate time-varying pressure differential
Controlled Pressure Source (TL) Generate time-varying pressure differential
Controlled Reservoir (TL) Thermal liquid reservoir at time-varying temperature
Controlled Voltage Source Ideal voltage source driven by input signal
Controlled Volumetric Flow Rate Source (2P) Generate time-varying volumetric flow rate
Controlled Volumetric Flow Rate Source (TL) Generate time-varying volumetric flow rate
Convective Heat Transfer Heat transfer by convection
Counter Increment output signal by 1 with every time step
Current Sensor Current sensor in electrical systems
Current-Controlled Current Source Linear current-controlled current source
Current-Controlled Voltage Source Linear current-controlled voltage source
Custom Hydraulic Fluid Working fluid properties, set by specifying parameter values
DC Current Source Ideal constant current source
DC Voltage Source Ideal constant voltage source
Diode Piecewise linear diode in electrical systems
Electrical Reference Connection to electrical ground
Electromagnetic Converter Lossless electromagnetic energy conversion device
Fluid Inertia Pressure differential across tube or channel due to change in fluid velocity
Flux Sensor Ideal flux sensor
Flux Source Ideal flux source
Fundamental Reluctance Simplified implementation of magnetic reluctance
Gas Properties Pneumatic domain properties for attached circuit
Gear Box Gear box in mechanical systems
Gyrator Ideal gyrator in electrical systems
Hydraulic Cap Hydraulic port terminator with zero flow
Hydraulic Constant Flow Rate Source Ideal source of hydraulic energy, characterized by constant flow rate
Hydraulic Constant Pressure Source Ideal source of hydraulic energy, characterized by constant pressure
Hydraulic Flow Rate Sensor Ideal flow meter
Hydraulic Flow Rate Source Ideal source of hydraulic energy, characterized by flow rate
Hydraulic Piston Chamber Variable volume hydraulic capacity in cylinders
Hydraulic Pressure Sensor Ideal pressure sensing device
Hydraulic Pressure Source Ideal source of hydraulic energy, characterized by pressure
Hydraulic Reference Connection to atmospheric pressure
Hydraulic Resistive Tube Hydraulic pipeline which accounts for friction losses only
Ideal Angular Velocity Source Ideal angular velocity source in mechanical rotational systems
Ideal Force Sensor Force sensor in mechanical translational systems
Ideal Force Source Ideal source of mechanical energy that generates force proportional to the input signal
Ideal Heat Flow Sensor Ideal heat flow meter
Ideal Heat Flow Source Ideal source of thermal energy, characterized by heat flow
Ideal Rotational Motion Sensor Motion sensor in mechanical rotational systems
Ideal Temperature Sensor Ideal temperature sensor
Ideal Temperature Source Ideal source of thermal energy, characterized by temperature
Ideal Torque Sensor Torque sensor in mechanical rotational systems
Ideal Torque Source Ideal source of mechanical energy that generates torque proportional to the input signal
Ideal Transformer Ideal transformer in electrical systems
Ideal Translational Motion Sensor Motion sensor in mechanical translational systems
Ideal Translational Velocity Source Ideal velocity source in mechanical translational systems
Inductor Linear inductor in electrical systems
Inertia Ideal mechanical rotational inertia
Infinite Flow Resistance (2P) Perfectly insulated barrier between two-phase fluid networks
Infinite Flow Resistance (TL) Perfectly insulated barrier between thermal liquid networks
Infinite Hydraulic Resistance Hydraulic element for setting initial pressure difference between two nodes
Infinite Pneumatic Resistance Pneumatic element for setting initial pressure and temperature difference between two nodes
Infinite Resistance Electrical element for setting initial voltage difference between two nodes
Infinite Thermal Resistance Thermal element for setting initial temperature difference between two nodes
Lever Generic mechanical lever
Linear Hydraulic Resistance Hydraulic pipeline with linear resistance losses
Local Restriction (2P) Fixed flow resistance
Local Restriction (TL) Time-invariant reduction in flow area
Magnetic Reference Reference connection for magnetic ports
Mass Ideal mechanical translational mass
Mass & Energy Flow Rate Sensor (TL) Measure mass and energy flow rates
Mass & Energy Flow Sensor (2P) Measure mass and energy flow rates
Mass Flow Rate Source (2P) Generate constant mass flow rate
Mass Flow Rate Source (TL) Generate constant mass flow rate
Mechanical Rotational Reference Reference connection for mechanical rotational ports
Mechanical Translational Reference Reference connection for mechanical translational ports
MMF Sensor Ideal magnetomotive force sensor
MMF Source Ideal magnetomotive force source
Mutual Inductor Mutual inductor in electrical systems
Op-Amp Ideal operational amplifier
Open Circuit Electrical port terminator that draws no current
Perfect Insulator Thermal element with perfect insulation and no thermal mass
Pipe (2P) Rigid conduit for fluid flow in two-phase fluid systems
Pipe (TL) Rigid conduit for fluid flow in thermal liquid systems
Pneumatic Absolute Reference Reference connection to zero absolute pressure and temperature for pneumatic ports
Pneumatic Atmospheric Reference Reference connection to ambient pressure and temperature for pneumatic ports
Pneumatic Flow Rate Source Ideal compressor with constant mass flow rate
Pneumatic Mass & Heat Flow Sensor Ideal mass flow and heat flow sensor
Pneumatic Piston Chamber Translational pneumatic piston chamber based on ideal gas law
Pneumatic Pressure & Temperature Sensor Ideal pressure and temperature sensor
Pneumatic Pressure Source Ideal compressor with constant pressure difference
Pneumatic Resistive Tube Pneumatic pipe accounting for pressure loss and added heat due to flow resistance
Pressure & Internal Energy Sensor (2P) Measure pressure and specific internal energy differences
Pressure & Temperature Sensor (TL) Measure pressure and temperature differences
Pressure Source (2P) Generate constant pressure differential
Pressure Source (TL) Generate constant pressure differential
PS Abs Output absolute value of input physical signal
PS Add Add two physical signal inputs
PS Ceil Output the smallest integer larger than or equal to input physical signal
PS Constant Generate constant physical signal
PS Constant Delay Delay input physical signal by specified time
PS Constant Offset Estimator Measure constant offset value of periodic signal
PS Dead Zone Provide region of zero output for physical signals
PS Divide Compute simple division of two input physical signals
PS Fix Round input physical signal toward zero
PS Floor Output the largest integer smaller than or equal to input physical signal
PS Gain Multiply input physical signal by constant
PS Harmonic Estimator (Amplitude, Phase) Measure harmonic amplitude and phase of periodic signal
PS Harmonic Estimator (Real, Imaginary) Measure real and imaginary parts of periodic signal harmonic
PS Integrator Integrate physical signal
PS Lookup Table (1D) Approximate one-dimensional function using specified lookup method
PS Lookup Table (2D) Approximate two-dimensional function using specified lookup method
PS Lookup Table (3D) Approximate three-dimensional function using specified lookup method
PS Math Function Apply mathematical function to input physical signal
PS Max Output maximum of two input physical signals
PS Min Output minimum of two input physical signals
PS Product Multiply two physical signal inputs
PS RMS Estimator Measure RMS value of periodic signal
PS Round Round input physical signal toward nearest integer
PS Saturation Limit range of physical signal
PS Sign Output sign of input physical signal
PS Subtract Compute simple subtraction of two input physical signals
PS Switch Single-pole double-throw switch controlled by external physical signal
PS Terminator Terminator for unconnected physical signal outputs
PS Variable Delay Delay input physical signal by variable time
PS-Simulink Converter Convert physical signal into Simulink output signal
Radiative Heat Transfer Heat transfer by radiation
Random Number Generate normally distributed random numbers for physical modeling
Reluctance Magnetic reluctance
Reluctance Force Actuator Magnetomotive device based on reluctance force
Repeating Sequence Output periodic piecewise linear signal
Reservoir (2P) Two-phase fluid reservoir at constant temperature and pressure
Reservoir (TL) Thermal liquid reservoir at constant temperature and pressure
Resistor Linear resistor in electrical systems
Rotary Pneumatic Piston Chamber Rotational pneumatic piston chamber based on ideal gas law
Rotational Damper Viscous damper in mechanical rotational systems
Rotational Electromechanical Converter Interface between electrical and mechanical rotational domains
Rotational Free End Rotational port terminator with zero torque
Rotational Friction Friction in contact between rotating bodies
Rotational Hard Stop Double-sided rotational hard stop
Rotational Hydro-Mechanical Converter Interface between hydraulic and mechanical rotational domains
Rotational Inerter Two-port inertia in mechanical rotational systems
Rotational Mechanical Converter (2P) Interface between two-phase fluid and mechanical rotational networks
Rotational Mechanical Converter (TL) Interface between thermal liquid and mechanical rotational networks
Rotational Pneumatic-Mechanical Converter Interface between pneumatic and mechanical rotational domains
Rotational Spring Ideal spring in mechanical rotational systems
Simscape Component Deploy Simscape language component as custom block in model diagram
Simulink-PS Converter Convert Simulink input signal into physical signal
Solver Configuration Physical Networks environment and solver configuration
Switch Switch controlled by external physical signal
Thermal Liquid Settings (TL) Fluid properties in thermal liquid network
Thermal Mass Mass in thermal systems
Thermal Reference Reference connection for thermal ports
Thermal Resistor Resistor with thermal port
Thermodynamic Properties Sensor (2P) Measure temperature, specific enthalpy, specific volume, and vapor quality
Translational Damper Viscous damper in mechanical translational systems
Translational Electromechanical Converter Interface between electrical and mechanical translational domains
Translational Free End Translational port terminator with zero force
Translational Friction Friction in contact between moving bodies
Translational Hard Stop Double-sided translational hard stop
Translational Hydro-Mechanical Converter Interface between hydraulic and mechanical translational domains
Translational Inerter Two-port inertia in mechanical translational systems
Translational Mechanical Converter (2P) Interface between two-phase fluid and mechanical translational networks
Translational Mechanical Converter (TL) Interface between thermal liquid and mechanical translational networks
Translational Spring Ideal spring in mechanical translational systems
Two-Phase Fluid Properties (2P) Fluid properties in two-phase fluid network
Two-Way Connection Two-way connector port for subsystem
Uniform Random Number Generate uniformly distributed random numbers for physical modeling
Variable Area Hydraulic Orifice Hydraulic variable orifice created by cylindrical spool and sleeve
Variable Area Pneumatic Orifice Sharp-edged variable-area orifice in pneumatic systems
Variable Hydraulic Chamber Hydraulic capacity of variable volume with compressible fluid
Variable Local Restriction (2P) Time-varying flow resistance
Variable Local Restriction (TL) Time-varying reduction in flow area
Variable Reluctance Variable reluctance in electromagnetic systems
Variable Resistor Linear variable resistor in electrical systems
Voltage Sensor Voltage sensor in electrical systems
Voltage-Controlled Current Source Linear voltage-controlled current source
Voltage-Controlled Voltage Source Linear voltage-controlled voltage source
Volumetric Flow Rate Sensor (TL) Measure volumetric flow rate
Volumetric Flow Rate Source (2P) Generate constant volumetric flow rate
Volumetric Flow Rate Source (TL) Generate constant volumetric flow rate
Volumetric Flow Sensor (2P) Measure volumetric flow rate
Wheel and Axle Wheel and axle mechanism in mechanical systems
この情報は役に立ちましたか?